濟南電纜橋架防火規范的測試方法

電纜橋架防火規范的測試方法主要包括以下幾種:

The testing methods for fire prevention regulations of cable trays mainly include the following:

外觀檢查:用目視檢查和手感檢查的方式,查看橋架表面有無裂紋、變形、銹蝕、劃傷等缺陷,尤其要注意防火涂層是否有脫落、起皮、起泡等情況,以及橋架連接處是否緊密,連接螺栓有無松動,連接處的密封膠條是否完好。

Appearance inspection: Use visual inspection and tactile inspection to check for defects such as cracks, deformation, rust, scratches, etc. on the surface of the bridge, especially paying attention to whether the fireproof coating has peeled off, peeled off, foamed, etc., as well as whether the bridge connections are tight, whether the connecting bolts are loose, and whether the sealing strips at the connections are intact.

尺寸與厚度測量:使用卡尺、千分尺等工具測量電纜橋架的尺寸,確保尺寸精度符合標準。采用厚度測量儀測量橋架板材厚度以及防火涂層厚度,保證其滿足設計要求和相關標準。不同類型的防火電纜橋架對防火涂層厚度有相應規定,如涂層厚度一般應不小于 60μm。

Measurement of Dimensions and Thickness: Use tools such as calipers and micrometers to measure the dimensions of cable trays, ensuring that the dimensional accuracy meets the standards. Use a thickness measuring instrument to measure the thickness of the bridge plate and the thickness of the fireproof coating, ensuring that they meet the design requirements and relevant standards. Different types of fire-resistant cable trays have corresponding regulations on the thickness of fire-resistant coatings, such as coating thickness should generally not be less than 60 μ m.

20221114120604238.jpg

機械性能測試:包括撞擊試驗和機械載荷試驗。撞擊試驗是使用撞擊試驗機模擬實際工況,評估電纜橋架在受到撞擊時的抗沖擊能力和結構穩定性,要求橋架經撞擊試驗后不應出現影響使用的變形和裂紋。機械載荷試驗則是利用載荷試驗機模擬實際負載,檢測電纜橋架在承受一定機械負載時的性能,要求橋架在承受工作載荷時,其相對撓度值≤10,卸載后不應有明顯變形。

Mechanical performance testing: including impact testing and mechanical load testing. Impact testing is the use of an impact testing machine to simulate actual working conditions, evaluate the impact resistance and structural stability of cable trays when subjected to impact, and require that the trays should not exhibit deformation or cracks that affect safe use after impact testing. Mechanical load testing is the use of a load testing machine to simulate actual loads and test the performance of cable trays under certain mechanical loads. It is required that the relative deflection value of the tray should be ≤ 10 when subjected to safe working loads, and there should be no significant deformation after unloading.

表面防護層性能測試:通過涂層測厚儀測量表面防護層厚度,使用附著力測試儀進行表面防護層附著力試驗,以評估防護層在長期使用過程中是否會脫落;采用均勻性測試儀進行表面防護層均勻性試驗,確保防護層整體防腐和耐火性能良好。

Surface protective layer performance testing: Measure the thickness of the surface protective layer using a coating thickness gauge, and conduct adhesion tests on the surface protective layer using an adhesion tester to evaluate whether the protective layer will peel off during long-term use; Use a uniformity tester to conduct uniformity tests on the surface protective layer, ensuring that the overall anti-corrosion and fire resistance performance of the protective layer is good.

耐火等級試驗:這是電纜橋架防火規范測試的關鍵項目。試驗在特定的耐火試驗爐中進行,需使爐內少含有一個橋架接頭且有足夠的與實際使用情況相符的連接件,并確保實現四面受火。試驗過程中,要嚴格按照標準時間 - 溫度曲線升溫,即(其中t為爐內的平均溫度,單位為℃;

Fire resistance rating test: This is a key item in the fire protection specification testing of cable trays. The experiment is conducted in a specific fire-resistant testing furnace, which must have at least one bridge joint and sufficient connectors that match the actual usage situation, and ensure that all four sides are exposed to fire. During the experiment, the temperature should be strictly raised according to the standard time temperature curve, where t is the average temperature inside the furnace, measured in ℃;

為時間,單位為 min),同時控制爐內壓力。試驗開始后,按頻次要求及時對爐內溫度及壓力進行測量與記錄,隨時觀察 3A 熔斷器情況,當橋架內電纜泄漏電流達到 3A 時,表明該橋架已不能維持其內部電纜繼續工作,喪失耐火能力,此時即為橋架的維持工作時間。若試驗中橋架仍能維持其內部電纜正常工作,但試驗已達到預定的維持工作時間時,也可終止試驗。

For time, in minutes, while controlling the pressure inside the furnace. After the experiment begins, the temperature and pressure inside the furnace should be measured and recorded in a timely manner according to the frequency requirements, and the condition of the 3A fuse should be observed at any time. When the leakage current of the cables in the bridge reaches 3A, it indicates that the bridge can no longer maintain its internal cables and lose its fire resistance ability. At this time, it is the maintenance working time of the bridge. If the bridge can still maintain the normal operation of its internal cables during the test, but the test has reached the predetermined maintenance time, the test can also be terminated.

此外,對于一些有條件的場所,還可定期委托機構對防火電纜橋架進行的防火性能檢測,確保其防火性能符合相關標準。

In addition, for some places with conditions, professional organizations can be regularly commissioned to conduct comprehensive fire performance testing on fire-resistant cable trays to ensure that their fire performance meets relevant standards.

 
qq
售前咨詢熱線
15168870138
售后咨詢熱線
13465410318
主站蜘蛛池模板: 日韩精品一区二区三区视频网 | 九九精品免费 | 久久精品中文字幕不卡一二区 | 成年人视频在线观看免费 | 天干天干天啪啪夜爽爽色 | 性久久久久 | 国产成人偷拍 | 2018av男人天堂 | 亚洲国产成人精彩精品 | 亚洲欧美在线视频 | 毛片网站免费在线观看 | 亚洲 欧美 激情 另类 自拍 | 欧美人禽杂交狂配毛片 | 九九久久久 | 亚洲欧美日韩久久一区 | 国产一级大片在线观看 | 亚洲国产精品久久网午夜 | 国产亚洲欧美在线视频 | 九九精品视频在线播放8 | 欧美一级毛片片aa视频 | 亚洲在线中文 | 99久久99这里只有免费费精品 | 亚洲欧美久久 | 日韩精品a | 成人手机看片 | 香港经典毛片a免费观看 | 免费观看欧美一级毛片 | 国产又粗又黄又湿又大 | 一区二区三区国产美女在线播放 | 久久久国产99久久国产首页 | 国产成人香蕉在线视频网站 | 亚洲国产精品成人午夜在线观看 | 国产人做人爱免费视频 | 国产一级做a爱片久久毛片a | jul-179在线中文字幕 | 欧美精品99久久久久久人 | 国产精品九九免费视频 | 国产精品漂亮美女在线观看 | 中文字幕中文字幕在线 | 日韩欧美一区二区精品久久 | 亚洲偷自拍另类图片二区 |